Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Diagnostics (Basel) ; 14(8)2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38667475

RESUMO

Radiologic usual interstitial pneumonia (UIP) patterns and concordant clinical characteristics define a diagnosis of idiopathic pulmonary fibrosis (IPF). However, limited expert access and high inter-clinician variability challenge early and pre-invasive diagnostic sensitivity and differentiation of IPF from other interstitial lung diseases (ILDs). We investigated a machine learning-driven software system, Fibresolve, to indicate IPF diagnosis in a heterogeneous group of 300 patients with interstitial lung disease work-up in a retrospective analysis of previously and prospectively collected registry data from two US clinical sites. Fibresolve analyzed cases at the initial pre-invasive assessment. An Expert Clinical Panel (ECP) and three panels of clinicians with varying experience analyzed the cases for comparison. Ground Truth was defined by separate multi-disciplinary discussion (MDD) with the benefit of surgical pathology results and follow-up. Fibresolve met both pre-specified co-primary endpoints of sensitivity superior to ECP and significantly greater specificity (p = 0.0007) than the non-inferior boundary of 80.0%. In the key subgroup of cases with thin-slice CT and atypical UIP patterns (n = 124), Fibresolve's diagnostic yield was 53.1% [CI: 41.3-64.9] (versus 0% pre-invasive clinician diagnostic yield in this group), and its specificity was 85.9% [CI: 76.7-92.6%]. Overall, Fibresolve was found to increase the sensitivity and diagnostic yield for IPF among cases of patients undergoing ILD work-up. These results demonstrate that in combination with standard clinical assessment, Fibresolve may serve as an adjunct in the diagnosis of IPF in a pre-invasive setting.

2.
J Imaging Inform Med ; 37(1): 297-307, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38343230

RESUMO

We previously validated Fibresolve, a machine learning classifier system that non-invasively predicts idiopathic pulmonary fibrosis (IPF) diagnosis. The system incorporates an automated deep learning algorithm that analyzes chest computed tomography (CT) imaging to assess for features associated with idiopathic pulmonary fibrosis. Here, we assess performance in assessment of patterns beyond those that are characteristic features of usual interstitial pneumonia (UIP) pattern. The machine learning classifier was previously developed and validated using standard training, validation, and test sets, with clinical plus pathologically determined ground truth. The multi-site 295-patient validation dataset was used for focused subgroup analysis in this investigation to evaluate the classifier's performance range in cases with and without radiologic UIP and probable UIP designations. Radiologic assessment of specific features for UIP including the presence and distribution of reticulation, ground glass, bronchiectasis, and honeycombing was used for assignment of radiologic pattern. Output from the classifier was assessed within various UIP subgroups. The machine learning classifier was able to classify cases not meeting the criteria for UIP or probable UIP as IPF with estimated sensitivity of 56-65% and estimated specificity of 92-94%. Example cases demonstrated non-basilar-predominant as well as ground glass patterns that were indeterminate for UIP by subjective imaging criteria but for which the classifier system was able to correctly identify the case as IPF as confirmed by multidisciplinary discussion generally inclusive of histopathology. The machine learning classifier Fibresolve may be helpful in the diagnosis of IPF in cases without radiological UIP and probable UIP patterns.

3.
Respir Med ; 219: 107428, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37838076

RESUMO

RATIONALE: Non-invasive diagnosis of idiopathic pulmonary fibrosis (IPF) involves identification of usual interstitial pneumonia (UIP) pattern by computed tomography (CT) and exclusion of other known etiologies of interstitial lung disease (ILD). However, uncertainty in identification of radiologic UIP pattern leads to the continued need for invasive surgical biopsy. We thus developed and validated a machine learning algorithm using CT scans alone to augment non-invasive diagnosis of IPF. METHODS: The primary algorithm was a deep learning convolutional neural network (CNN) with model inputs of CT images only. The algorithm was trained to predict IPF among cases of ILD, with reference standard of multidisciplinary discussion (MDD) consensus diagnosis. The algorithm was trained using a multi-center dataset of more than 2000 cases of ILD. A US-based multi-site cohort (n = 295) was used for algorithm tuning, and external validation was performed with a separate dataset (n = 295) from European and South American sources. RESULTS: In the tuning set, the model achieved an area under the receiver operating characteristic curve (AUC) of 0.87 (CI: 0.83-0.92) in differentiating IPF from other ILDs. Sensitivity and specificity were 0.67 (0.57-0.76) and 0.90 (0.83-0.95), respectively. By contrast, pre-recorded assessment prior to MDD diagnosis had sensitivity of 0.31 (0.23-0.42) and specificity of 0.92 (0.87-0.95). In the external test set, c-statistic was also 0.87 (0.83-0.91). Model performance was consistent across a variety of CT scanner manufacturers and slice thickness. CONCLUSION: The presented deep learning algorithm demonstrated consistent performance in identifying IPF among cases of ILD using CT images alone and suggests generalization across CT manufacturers.


Assuntos
Aprendizado Profundo , Fibrose Pulmonar Idiopática , Doenças Pulmonares Intersticiais , Humanos , Fibrose Pulmonar Idiopática/diagnóstico , Doenças Pulmonares Intersticiais/diagnóstico por imagem , Doenças Pulmonares Intersticiais/patologia , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Pulmão/diagnóstico por imagem , Pulmão/patologia , Estudos Retrospectivos
4.
J Clin Med Res ; 15(8-9): 423-429, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37822853

RESUMO

Background: Improvement in recognition and referral of pulmonary fibrosis (PF) is vital to improving patient outcomes within interstitial lung disease. We determined the performance metrics and processing time of an artificial intelligence triage and notification software, ScreenDx-LungFibrosis™, developed to improve detection of PF. Methods: ScreenDx-LungFibrosis™ was applied to chest computed tomography (CT) scans from multisource data. Device output (+/- PF) was compared to clinical diagnosis (+/- PF), and diagnostic performance was evaluated. Primary endpoints included device sensitivity and specificity > 80% and processing time < 4.5 min. Results: Of 3,018 patients included, PF was present in 22.9%. ScreenDx-LungFibrosis™ detected PF with a sensitivity and specificity of 91.3% (95% confidence interval (CI): 89.0-93.3%) and 95.1% (95% CI: 94.2-96.0%), respectively. Mean processing time was 27.6 s (95% CI: 26.0 - 29.1 s). Conclusions: ScreenDx-LungFibrosis™ accurately and reliably identified PF with a rapid per-case processing time, underscoring its potential for transformative improvement in PF outcomes when routinely applied to chest CTs.

5.
Respir Investig ; 60(3): 430-433, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35181263

RESUMO

Patients with lymphangioleiomyomatosis (LAM) frequently experience delays in diagnosis, owing partly to the delayed characterization of imaging findings. This project aimed to develop a machine learning model to distinguish LAM from other diffuse cystic lung diseases (DCLDs). Computed tomography scans from patients with confirmed DCLDs were acquired from registry datasets and a recurrent convolutional neural network was trained for their classification. The final model provided sensitivity and specificity of 85% and 92%, respectively, for LAM, similar to the historical metrics of 88% and 97%, respectively, by experts. The proof-of-concept work holds promise as a clinically useful tool to assist in recognizing LAM.


Assuntos
Pneumopatias , Neoplasias Pulmonares , Linfangioleiomiomatose , Humanos , Pneumopatias/diagnóstico por imagem , Neoplasias Pulmonares/diagnóstico por imagem , Linfangioleiomiomatose/diagnóstico por imagem , Aprendizado de Máquina , Tomografia Computadorizada por Raios X/métodos
7.
J Magn Reson Imaging ; 49(4): 984-993, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30390358

RESUMO

BACKGROUND: View-sharing (VS) increases spatiotemporal resolution in dynamic contrast-enhanced (DCE) MRI by sharing high-frequency k-space data across temporal phases. This temporal sharing results in respiratory motion within any phase to propagate artifacts across all shared phases. Compressed sensing (CS) eliminates the need for VS by recovering missing k-space data from pseudorandom undersampling, reducing temporal blurring while maintaining spatial resolution. PURPOSE: To evaluate a CS reconstruction algorithm on undersampled DCE-MRI data for image quality and hepatocellular carcinoma (HCC) detection. STUDY TYPE: Retrospective. SUBJECTS: Fifty consecutive patients undergoing MRI for HCC screening (29 males, 21 females, 52-72 years). FIELD STRENGTH/SEQUENCE: 3.0T MRI. Multiphase 3D-SPGR T1 -weighted sequence undersampled in arterial phases with a complementary Poisson disc sampling pattern reconstructed with VS and CS algorithms. ASSESSMENT: VS and CS reconstructions evaluated by blinded assessments of image quality and anatomic delineation on Likert scales (1-4 and 1-5, respectively), and HCC detection by OPTN/UNOS criteria including a diagnostic confidence score (1-5). Blinded side-by-side reconstruction comparisons for lesion depiction and overall series preference (-3-3). STATISTICAL ANALYSIS: Two-tailed Wilcoxon signed rank tests for paired nonparametric analyses with Bonferroni-Holm multiple-comparison corrections. McNemar's test for differences in lesion detection frequency and transplantation eligibility. RESULTS: CS compared with VS demonstrated significantly improved contrast (mean 3.6 vs. 2.9, P < 0.0001) and less motion artifact (mean 3.6 vs. 3.2, P = 0.006). CS compared with VS demonstrated significantly improved delineations of liver margin (mean 4.5 vs. 3.8, P = 0.0002), portal veins (mean 4.5 vs. 3.7, P < 0.0001), and hepatic veins (mean 4.6 vs. 3.5, P < 0.0001), but significantly decreased delineation of hepatic arteries (mean 3.2 vs. 3.7, P = 0.004). No significant differences were seen in the other assessments. DATA CONCLUSION: Applying a CS reconstruction to data acquired for a VS reconstruction significantly reduces motion artifacts in a clinical DCE protocol for HCC screening. LEVEL OF EVIDENCE: 3 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2019;49:984-993.


Assuntos
Artefatos , Carcinoma Hepatocelular/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Imageamento por Ressonância Magnética , Idoso , Algoritmos , Meios de Contraste , Compressão de Dados , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Movimento (Física) , Variações Dependentes do Observador , Reconhecimento Automatizado de Padrão , Respiração , Estudos Retrospectivos
8.
Semin Intervent Radiol ; 33(2): 137-43, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27247483

RESUMO

Owing to a myriad of inferior vena cava (IVC) filter types and their potential complications, rapid and correct identification may be challenging when encountered on routine imaging. The authors aimed to develop an interactive mobile application that allows recognition of all IVC filters and related complications, to optimize the care of patients with indwelling IVC filters. The FDA Premarket Notification Database was queried from 1980 to 2014 to identify all IVC filter types in the United States. An electronic search was then performed on MEDLINE and the FDA MAUDE database to identify all reported complications associated with each device. High-resolution photos were taken of each filter type and corresponding computed tomographic and fluoroscopic images were obtained from an institutional review board-approved IVC filter registry. A wireframe and storyboard were created, and software was developed using HTML5/CSS compliant code. The software was deployed using PhoneGap (Adobe, San Jose, CA), and the prototype was tested and refined. Twenty-three IVC filter types were identified for inclusion. Safety data from FDA MAUDE and 72 relevant peer-reviewed studies were acquired, and complication rates for each filter type were highlighted in the application. Digital photos, fluoroscopic images, and CT DICOM files were seamlessly incorporated. All data were succinctly organized electronically, and the software was successfully deployed into Android (Google, Mountain View, CA) and iOS (Apple, Cupertino, CA) platforms. A powerful electronic mobile application was successfully created to allow rapid identification of all IVC filter types and related complications. This application may be used to optimize the care of patients with IVC filters.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...